Get in touch with LFADJ Company
Lamp Energy Planner
Estimate lamp-only electrical energy for a fixed output setting and shift. This calculation does not predict battery runtime, charging performance, diesel fuel use or lighting coverage.
Calculation method
Lamp energy (kWh) = watts per lamp × lamps per tower × operating hours ÷ 1,000. Fleet energy multiplies this result by the number of towers.
- Example: 4 × 100 W × 8 h ÷ 1,000 = 3.2 kWh per tower.
- Use measured electrical input for the intended output setting when available.
- Add driver, controls, battery, inverter and charging losses separately; nameplate battery capacity is not usable energy.
U.S. Energy Information Administration: measuring electricity