The best LED flood light manufacturers are Dialight for heavy-industry sites, Phoenix Lighting for high-mast and port floods, Signify for area projects specified per size, RAB Lighting for distributor-channel retrofits and Schreder for stadiums. LFADJ, the publisher of this guide, handles explosion-proof project RFQs.

Output and efficiency are more important than brand when distinguishing these makers. Across 16 published entries, lumens per watt runs from 80 to 200, and two entries fall under the 118 lm/W line US federal buyers use for floodlight luminaires. With LED technology, brightness alone no longer separates these makers, so compare energy efficiency and light control for outdoor applications.

Quick Picks: Best LED Flood Light Manufacturers by Job

Which LED flood light maker fits which job, from explosion-proof RFQs at LFADJ to stadium systems at Schreder and Musco.
  • Best for explosion-proof project RFQs matched to a documented hazardous-area brief: LFADJ (publisher)
  • Best for heavy industry with a 10-year warranty: Dialight
  • Best for high-mast, port and marine floods: Phoenix Lighting
  • Best for distributor-channel retrofits: RAB Lighting
  • Best for stadiums and very large areas: Schreder and Musco Lighting
  • Best for factory-direct OEM export: AGC Lighting

Disclosure: This guide is published by LFADJ. We list ourselves first because this is our website, not because we claim to be the market leader. The other 19 manufacturers are grouped by what they are best for, in no particular order within each group.

How We Selected These LED Flood Light Manufacturers

Entry rule for this list: own LED flood design or factory and a named flood model; resellers and directories left out.

Each company had to design or build its own LED flood luminaires and name a flood model, family or lighting system on its site. Resellers and distributors without their own design or factory, directories, sourcing platforms, and consumer security-light and bulb brands were excluded. Company information was verified against their official websites and public sources in November 2026.

The list covers outdoor LED flood lights for commercial, industrial and hazardous-area work rather than retail security lighting. Cree Lighting is not on the list: Inside Lighting reported in September 2026 that its commercial assets were sold in May 2026 and that Phoenix Lighting now holds the rights to the product lines, so those floods are now licensed to Phoenix. The lighting market also holds many resellers of LED products, and a leading LED brand name alone didn’t earn a place: each company had to name a flood line we could read. Readers who only need certified hazardous fixtures of every type can start with our list of explosion proof lighting manufacturers.

LED Flood Light Manufacturers Compared

20 LED flood light makers in four groups: hazardous 1-8, North American 9-12, European 13-17, China exporters 18-20.

Use this table to shortlist three to five floodlight manufacturers, then read their cards for the limits. Some sell an extensive range of outdoor flood lights, others only narrow hazardous lines, so start from your lighting needs. The lumens and lm/W figures are provided by the makers.

20 LED flood light manufacturers compared by job, flood model and limit, with published lumens and lm/W where makers state them.
No. Company Name Headquarters Founded Year Best For Brief Introduction Flood Model Key Advantages Potential Disadvantages Official Website
1 LFADJ Yueqing, China 2013 Explosion-proof project RFQs Industrial, mobile and explosion-proof lighting maker Explosion-proof LED flood, configured per project Samples in 15-25 working days Approval per model; MOQ 50-100 lfadjlight.com
2 Dialight United Kingdom 1938 Heavy industry, long warranty LSE-listed industrial LED lighting maker ProSite, 12,000-65,000 lm, up to 165 lm/W 10-year warranty UL 844 gas rating stops at Class I Division 2 www.dialight.com
3 Eaton Crouse-Hinds Dublin, Ireland 1897 Division 2 and Zone 2 areas Hazardous-area product series of Eaton Champ FMVA, 3,000-50,000 lm Eleven versions, up to IP66/67 No Class I Division 1 gas rating www.eaton.com
4 Phoenix Lighting Milwaukee, USA 1944 High-mast, port, marine Harsh-environment fixture maker Highland 500, 530 W, 80,000 lm L70 above 100,000 hours SLX Division 1 reaches 4,600 lm www.phoenixlighting.com
5 Larson Electronics Texas, USA 1973 Small hazardous orders, listed price Hazardous lights and panel shop EPL-LED-100W-RT, 100 W, 14,000 lm Published list price Groups C and D only www.larsonelectronics.com
6 Hubbell Killark Fenton, USA (service address) 1913 Division 2 with dust or fibers Harsh and hazardous brand of Hubbell KFL-X high-lumen flood Marine rated, Type 4X, IP66 Gas rating stops at Class I Division 2 www.hubbell.com/killark
7 Warom Technology Shanghai, China 1987 High-output Zone 1 floods Listed explosion-proof equipment maker BAT86, 9,427-81,156 lm ATEX, IECEx and Division 1 Groups B, C, D, not A www.waromgroup.com
8 OKTECH Shenzhen, China 1995 Power and petrochemical EPC Ocean’s King professional lighting brand BFC8616, Zone 1, up to 150 W Flood plus portable Ex range BFC8616 lists CCC, CNEX only www.oceansking.com
9 Current Lighting Greenville, USA 2022 Metal halide yard replacement Lighting and controls maker, formerly GE Current Evolve EFH, 18,000-39,000 lm Four distribution options Lower top lumen band www.currentlighting.com
10 Acuity Lithonia Lighting Atlanta, USA 1946 Stocked contractor floods Lighting brand of Acuity ESXF, RSXF, High Lumen up to 105,000 lm 36 ESXF configurations ESXF has one 7×7 beam lithonia.acuitybrands.com
11 RAB Lighting Cranbury, USA 1946 Distributor-channel retrofits Maker selling through electrical distributors FFLED, 16,700-34,000 lm, up to 152 lm/W DLC listed families, IP66 No direct factory route www.rablighting.com
12 Musco Lighting Oskaloosa, USA 1976 Stadium systems Sports and large-area project supplier Designed sports systems LA28 broadcast lighting role Project sale, no catalog lm/W www.musco.com
13 Signify Eindhoven, Netherlands 2016 Area projects specified per size Listed lighting maker, spun off from Philips ClearFlood gen2, 172 W, 151 lm/W Per-size data, IP66, IK08 6/8 kV surge on ClearFlood www.signify.com
14 LEDVANCE Garching, Germany 2016 North American contractors General lighting maker in 140+ countries Floodlight Opti-Select, up to 470 W 50+ branches Stops at 470 W; cULus range www.ledvance.com
15 Schreder Liege, Belgium 1907 Stadiums, 20 kV surge Family-founded lighting maker OMNIBLAST, up to 247,400 lm Up to 172 lm/W Remote gear box planning www.schreder.com
16 Lena Lighting Sroda Wielkopolska, Poland 1989 Corrosive European sites Warsaw-listed luminaire maker Factor LED, up to 150,800 lm C5, IP67, IK10 on Quest Evo Factor LED stops at IK09 lenalighting.com
17 Thorn Lighting Spennymoor, UK 1928 Sports, light-spill control Zumtobel Group lighting maker Altis, up to 217,000 lm Tilting modules, spill control Separate gearbox from Thorn www.thornlighting.com
18 OPPLE Lighting Shanghai, China 1996 Entry-level to high-output trade Integrated lighting company Performer HO, 80,000 lm, 130 lm/W Entry-level and high-output tiers EcoMax II at 80 lm/W www.opple.com
19 AGC Lighting Shenzhen, China 2014 OEM and private-label export Industrial and hazardous lighting maker FL35 up to 240,000 lm; FL55 180 lm/W 120+ countries served 5-year warranty on FL57, FL84 www.agcled.com
20 Hpwinner Hangzhou, China 2011 Simulated high-mast projects Outdoor LED maker, 800+ staff High-mast and airport floods 700+ patents Range leads with roadway www.hpwinner.com

Founded Year shows the start of the named brand or business: Crouse-Hinds and Lithonia use the brand’s first year, Phoenix uses its 1944 start in lighting fixtures, Current uses its 2022 rebrand, and Signify uses its 2016 separation from Philips.

118-Line Flood Efficacy Ladder: Lumens per Watt by Model

16 LED flood entries by lm/W rung: 7 at 150 and up, 7 from 118 to 149, 2 below 118 (US FEMP 118 lm/W floodlight line).

The 118-Line Flood Efficacy Ladder compares 16 entries, mixing published family peaks with specific-size figures, against one public benchmark. We took watts and lumens from each maker’s page and divided them where they didn’t state lm/W. Seven entries reach 150 lm/W or more, seven entries are between 118 and 149, and two entries are less than 118.

118-Line Flood Efficacy Ladder: 16 LED flood entries grouped by lumens-per-watt rung against the 118 lm/W FEMP floodlight line.
Model and size Maker Watts Lumens lm/W How the figure was read Rung
Quest LED Evo Lena Lighting Not applicable Not applicable 200 Family peak, published 150 and up
FL55, PC lens AGC Lighting 50-300 Not applicable 180 Family peak, published 150 and up
OMNIBLAST Schreder 367-1,740 40,700-247,400 172 Family peak, published 150 and up
ProSite Floodlight Dialight Not applicable 12,000-65,000 165 Family peak, published 150 and up
FFLED RAB Lighting 120-230 16,700-34,000 152 Family peak, published 150 and up
ClearFlood gen2 Signify 172 25,900 151 This size, published 150 and up
Highland 500 Phoenix Lighting 530 80,000 150.9 Calculated, 80,000 / 530 150 and up
Factor LED, one module, 45 degrees Lena Lighting 101 15,000 148.5 Calculated, 15,000 / 101 118 to 149
OMNISTAR-MIDI, highest output Schreder 226 32,318 143 Calculated, 32,318 / 226 118 to 149
SafeSite Floodlight, 130 W Dialight 130 18,600 143 This size, APAC spec sheet 118 to 149
EPL-LED-100W-RT Larson Electronics 100 14,000 140 Calculated, 14,000 / 100 118 to 149
FXLED RAB Lighting 200-500 31,000-63,000 132 Family peak, published 118 to 149
Performer HO OPPLE Lighting Not applicable Up to 80,000 130 Family peak, published 118 to 149
SmartBright G3, top size Signify 300 36,000 120 Calculated, 36,000 / 300 118 to 149
SLX Phoenix Lighting 44 4,600 104.5 Calculated, 4,600 / 44 Below 118
EcoMax II, 30 W OPPLE Lighting 30 2,400 80 This size, published Below 118

One of the two entries below the line is a Division 1 hazardous flood, SLX. The other is a budget tier. Consider the job before eliminating a fixture. Traditional flood lights such as metal halide needed more power and frequent replacements, so a modern LED retrofit can still pay on a tall pole even below the line.

Worked example: Phoenix lists its Highland 500 at 530 W and up to 80,000 lumens, so 80,000 / 530 = 150.9 lm/W. Schreder’s OMNISTAR-MIDI page lists “up to” 152 lm/W, yet its highest-output row gives 32,318 lm at 226 W, or 143 lm/W. A family maximum describes its highest-efficacy configuration; the optics, light-quality options and operating conditions of the quoted fixture may yield a lower figure.

What lumens per watt should a commercial LED flood light deliver?

Shoot for 118 lm/W or better, the figure the US Federal Energy Management Program lists for floodlight luminaires, and request 150 lm/W on new outdoor lighting specified on energy savings. Seven of the 16 entries publish 150 lm/W or more, most of them as family peaks, so ask for the figure at the size you order.

That 118 lm/W line binds covered US federal purchases and is no global rule, so private buyers use it as a yardstick. Three rungs turn the ladder into a decision. Below 118 lm/W, ask why; a Division 1 rating alone doesn’t explain it, since Larson’s Division 1 flood calculates to 140 lm/W. From 118 to 149 lm/W, compare price, surge, and warranty. From 150 lm/W and up, compare controls and optics. Better lighting technology with higher efficacy also means less heat output for the same light, and good heat dissipation is what supports an extended lifespan on a pole that’s costly to reach. Long-term value needs efficiency and durability together: an energy-efficient LED flood with a 5-year warranty and one with 10 years are different buys, so read efficacy next to the warranty.

Hazardous-Area and Heavy-Industry Flood Builders (Companies 1–8)

Hazardous LED floods by marking: ProSite, Champ FMVA, Command Flood, KFL-X stop at Division 2; SLX, BAT86 reach Division 1.

These eight makers build floods for classified and harsh sites such as refineries, ports and plants. Four floods in this group stop at Class I Division 2: Dialight ProSite, Eaton Champ FMVA, Phoenix Command Flood and Killark KFL-X. Division 1 options include Phoenix SLX and Warom BAT86. ATEX is the EU regulatory framework for explosion protection, while IECEx is an international certification system for equipment used in explosive atmospheres, tested against IEC international standards. Security and safety lighting inside a classified area is held to the same marking rules as any other fixture.

1. LFADJ: Best for explosion-proof project RFQs matched to a documented hazardous-area brief

Headquarters: Yueqing, Zhejiang, China · Founded: 2013 · Type: manufacturer covering R&D, manufacturing, trade and service (Zhejiang Longfa Lighting Co., Ltd.)

Official website: https://lfadjlight.com/

Main products: explosion-proof LED flood lights, mobile light towers, portable work lights, emergency lighting

Flood model and specs: configured per project; certified samples in 15-25 working days after technical confirmation, production 25-35 days after deposit (published by LFADJ)

Certifications / notable work: ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 for the management system; 2018 Panjin municipal-government procurement contract

LFADJ starts a flood quote from the classified location, then matches the optics and documents to it, which suits EPC teams with an area-classification schedule in hand. Its explosion-proof lighting range sits beside mobile towers in the same catalog. The flood page publishes no fixed model table, lm/W figure or flood marking, approval scope is confirmed per model at quote, and the 50-100 piece planning MOQ doesn’t suit a single replacement flood.

2. Dialight: Best for heavy-industry and Division 2 sites that want a 10-year warranty

Headquarters: United Kingdom · Founded: 1938 · Type: LSE-listed maker of LED lighting for industrial applications

Official website: https://www.dialight.com/

Main products: ProSite Floodlight, ProSite High Mast, ProSite Battery Backup, SafeSite High Lumen Floodlight

Flood model and specs: ProSite Floodlight 12,000-65,000 lumens, up to 165 lm/W, up to 100 ft mounting height

Certifications / notable work: ProSite UL 844 (CID2, CIID1, CIID2, CIII), CSA, IECEx/ATEX Zone 2, 21 and 22; SafeSite IECEx/ATEX Zone 1, 21, 2 and 22

Dialight pairs ProSite and SafeSite floods with a 10-year warranty, which matters when a failed fixture means a lift rental and a permit. SafeSite runs from -40 to +60 °C with sizes such as 18,600 lumens at 130 W for outdoor Zone 1 work. Dialight’s October 2025 APAC spec sheet prints 143 lm/W at that size, while the product page shows up to 111 lm/W. ProSite UL 844 gas coverage stops at Class I Division 2, so Zone 1 work moves to the separate SafeSite family.

3. Eaton Crouse-Hinds: Best for Class I Division 2 and Zone 2 process areas

Headquarters: Dublin, Ireland (Eaton global headquarters) · Founded: 1897 as Crouse-Hinds Electric Company · Type: product series of Eaton, a power management company

Official website: https://www.eaton.com/

Main products: Champ FMVA LED hazardous-area floodlights in eleven versions

Flood model and specs: 3,000 to 50,000 lumens; 9,000-25,000 lumen models listed Type 4X and IP66/67

Certifications / notable work: Class I Division 2 Groups A, B, C, D; Class I Zone 2; Class II Division 1 Groups E, F, G; IECEx ETL 25.0055X on 9,000-25,000 lumen models; UL844 and UL1598

Eleven Champ FMVA versions give one family across small and large process areas. Marking options reach +65 °C on the 9,000-25,000 lumen models. Champ FMVA gas ratings stop at Class I Division 2 and Zone 2, so a Class I Division 1 area needs another fixture.

4. Phoenix Lighting: Best for high-mast, port and marine floods up to 80,000 lumens

Headquarters: Milwaukee, Wisconsin, USA · Founded: 1944 in lighting fixtures · Type: lighting designer and manufacturer

Official website: https://www.phoenixlighting.com/

Main products: Highland high-mast floods, Command Flood marine and port floods, SLX explosion-proof floods

Flood model and specs: Highland 500: 530 W, up to 80,000 lumens; Command Flood CF-375: up to 48,000 lumens

Certifications / notable work: Command Flood UL 1598A marine, UL 844 Class I Division 2 Groups A-D; SLX UL 844 Class I Division 1 Groups C and D

Phoenix aims its range at the world’s harshest outdoor work, and Highland lists L70 above 100,000 hours and IP66 compliance, a natural pick for container terminals and high-mast yards where replacement is expensive. Inside Lighting reports that a Phoenix spokesperson confirmed exclusive, global and indefinite license rights to the former Cree Lighting commercial and industrial portfolio, including OSQ area and flood lights and OL low-profile floods, with shipments under the Phoenix name expected in the first quarter of 2027. The SLX Class I Division 1 flood covers Groups C and D only and tops out at 4,600 lumens.

5. Larson Electronics: Best for small-quantity hazardous floods with a published list price

Headquarters: Texas, USA · Founded: 1973 · Type: manufacturer and certified panel shop, including custom built-to-spec units

Official website: https://www.larsonelectronics.com/

Main products: explosion-proof flood, high bay, linear, string and portable lights, plus light towers

Flood model and specs: EPL-LED-100W-RT: 100 W, 14,000 lumens, listed price $3,612.24 as of November 2026

Certifications / notable work: ISO 9001:2015; according to its website, a certified panel shop for electrical control and explosion-proof equipment

Larson shows a price on the page, which is rare in this category and helps a maintenance buyer budget one fixture without a quote cycle. According to its website, the lights in its explosion-proof category are made in the USA, and systems are also available for rent. The EPL-LED-100W-RT covers Class I Groups C and D, so hydrogen and acetylene areas need another fixture.

6. Hubbell Killark: Best for Division 2 areas with dust or fibers that also need a marine rating

Headquarters: Fenton, Missouri, USA (Killark customer service address) · Founded: 1913 · Type: brand of Hubbell’s Harsh and Hazardous division

Official website: https://www.hubbell.com/killark/en

Main products: KFL-X series high-lumen LED floodlights

Flood model and specs: KFL-X, Type 3, 4X and IP66; marine rated (US only)

Certifications / notable work: Class I Division 2 Groups A, B, C, D; Class II Division 1 and 2 Groups E, F, G; Class III; CSA-C-US; Ex tb IIIC T95 °C Db

KFL-X suits sites where dust and salt air meet a Division 2 gas rating, since it carries Class II and Class III coverage plus Zone 2 and Zone 21 marking, and Killark has built hazardous-location products since 1913. KFL-X gas coverage stops at Class I Division 2.

7. Warom Technology: Best for high-output Zone 1 floods with certificates published online

Headquarters: Jiading District, Shanghai, China · Founded: 1987 · Type: listed manufacturer (Shanghai Stock Exchange, code 603855)

Official website: https://www.waromgroup.com/

Main products: BAT86 series explosion-proof LED floodlight

Flood model and specs: BAT86 rated luminous flux 9,427 to 81,156 lm; 100-277 V AC; IP66

Certifications / notable work: IECEx CQM 21.0015X, ATEX II 2 G Ex db IIB+H2, Class I Division 1 Groups B, C, D

BAT86 pairs a high top output with Zone 1 and Division 1 marking, a combination few floods here offer, and the certificate number sits on the product page for a quick check. Oil, chemical and pharmaceutical sites appear among its listed solutions. BAT86 is marked IIB+H2 and Class I Division 1 Groups B, C, D, so a Group A atmosphere needs another fixture.

8. OKTECH (Ocean’s King Lighting): Best for power-plant and petrochemical EPC packages

Headquarters: Guangming New District, Shenzhen, China · Founded: 1995 · Type: manufacturer of professional lighting trading under the OKTECH brand

Official website: https://www.oceansking.com/

Main products: LED flood lights for hazardous locations, explosion-proof high bays, portable Ex work lights

Flood model and specs: BFC8616: 100 or 150 W, 140 lm/W, IP66, Zone 1 and Zone 2; BFC8115A: 50 or 100 W, Zone 2 and Zone 21; project pages list model codes such as NFC9281

Certifications / notable work: according to its website, luminaires built for ATEX, IECEx and SASO requirements, with approvals from BASEEFA, DNV and CQST; DUBAL CCPP H-Class combined-cycle plant among its projects

According to a third-party company profile, OKTECH supplies more than 10 industries through 10 business departments, so one contractor can buy flood and portable Ex lights from a single source for a plant package, and its site lists petrochemical plant applications among its solutions. The Zone 1 BFC8616 lists CCC and CNEX approvals and stops at 150 W, so an ATEX job or a high-mast yard needs another model.

North American Commercial and Sports Flood Lines (Companies 9–12)

North American LED flood makers compared: RAB through distributors, Lithonia stocked in 1-2 days, Musco as projects.

These four makers cover commercial outdoor lighting in North America, from contractor jobs and yards to sports fields and other outdoor areas. They differ most on channel: RAB sells only through electrical distributors, Lithonia stocks Contractor Select lines, and Musco sells complete projects.

Which LED flood light companies are based in the USA?

RAB Lighting, Acuity’s Lithonia, Current, Musco, Phoenix, Larson and Killark are the US-based LED flood light companies on this list. Larson states that the lights in its explosion-proof category are made in the USA, and Lithonia offers a Buy America(n) option on RSXF floods.

9. Current Lighting: Best for replacing 400-1,000 W metal halide floods on yards

Headquarters: Greenville, South Carolina, USA · Founded: 2022 in current form, when GE Current bought Hubbell’s commercial and industrial lighting · Type: lighting and controls manufacturer

Official website: https://www.currentlighting.com/

Main products: Evolve EFH high-output, EFM medium-output and EFC compact LED flood lights

Flood model and specs: Evolve EFH: 18,000-39,000 lumens with 6×5, 6×6, 7×6 and 7×7 distributions; EFC 2,000-12,000 lumens

Certifications / notable work: formed from GE Current and Hubbell’s commercial and industrial lighting business

Evolve is written around one retrofit job: the EFH sheet names 250-400 W high-pressure sodium and 400-1,000 W metal halide lights as the fixtures it replaces. Four distributions cover yards and walkway edges without changing family. The EFH band of 18,000-39,000 lumens sits below the 100,000-lumen floods on this list, so very tall masts point to a higher-output family.

10. Acuity Lithonia Lighting: Best for US contractors who need stocked, field-adjustable floods

Headquarters: Atlanta, Georgia, USA · Founded: 1946 (Lithonia Lighting) · Type: lighting brand of parent group Acuity

Official website: https://lithonia.acuitybrands.com/

Main products: ESXF all-in-one floods, RSXF floods, High Lumen LED floodlights, D-Series floods

Flood model and specs: High Lumen floods up to 105,000 lumens replacing up to 1,500 W HID; RSXF1 up to 23,000 and RSXF2 up to 44,000 lumens

Certifications / notable work: ESXF DLC Premium; RSXF DLC Standard with a Buy America(n) option

ESXF puts 36 configurations in one product, with selectable lumens, color temperature and photocell, and its Contractor Select stock ships in 1-2 days. That saves a contractor from carrying several part numbers to a job. ESXF ships with one wide 7×7 distribution, so long-throw aiming points to the RSXF or High Lumen families.

11. RAB Lighting: Best for distributor-channel retrofits of metal halide floods

Headquarters: Cranbury, New Jersey, USA · Founded: 1946 · Type: lighting manufacturer selling only through electrical distributors

Official website: https://www.rablighting.com/

Main products: FXLED, FFLED and EZLED flood families

Flood model and specs: FFLED 120-230 W: 16,700-34,000 lumens, up to 152 lm/W; FXLED 200-500 W: 31,000-63,000 lumens, up to 132 lm/W

Certifications / notable work: DLC Standard and Premium on the listed families; IP66; 5-year warranty

RAB maps each family to the old lamp it replaces: the FFLED 230 W is listed against up to 1000 W metal halide, and slipfitter or trunnion mounts match existing poles. A knuckle mount is offered on the small FFLED. Products are sold exclusively through electrical distributors, so there’s no direct factory price or OEM route.

12. Musco Lighting: Best for stadium and sports-field lighting bought as a supported system

Headquarters: Oskaloosa, Iowa, USA · Founded: 1976 · Type: sports and large-area lighting project supplier

Official website: https://www.musco.com/

Main products: sports and large-area LED lighting systems, video boards and light shows

Flood model and specs: sold as designed systems such as TLC for LED; project support described as 24/7/365 with a long-term warranty

Certifications / notable work: named Official Sport Presentation and Broadcast Lighting Provider for the LA28 Olympic and Paralympic Games

Musco fits a school district or stadium owner who wants one party guiding the project from funding through long-term warranty rather than a box of fixtures. Musco sells designed sports and large-area projects rather than catalog floods by the piece, so compare efficacy using the fixtures named in the project proposal.

European Project Floods (Companies 13–17)

European makers compared: Signify 151 lm/W per size, Schreder up to 247,400 lm, Lena IK10 and C5, Thorn 217,000 lm.

These five makers serve large areas from sports fields to industrial yards, and several publish the most complete per-size data on this list. Surge, impact and corrosion figures vary widely, so the site usually determines the choice rather than the brand.

13. Signify: Best for area and recreational projects specified on per-size lm/W data

Headquarters: Eindhoven, the Netherlands · Founded: founded as Philips; listed separately since May 2016 · Type: listed lighting manufacturer

Official website: https://www.signify.com/

Main products: ClearFlood gen2 BVP655 and Philips SmartBright G3 floodlights

Flood model and specs: ClearFlood gen2: 172 W, 25,900 lm, 151 lm/W, IP66, IK08; SmartBright G3: up to 36,000 lm at 300 W

Certifications / notable work: IP66 and IK08 listed per ClearFlood size, Safety class I

Signify publishes watts, lumens and lm/W for each ClearFlood size, which lets a specifier compare by the row rather than the family. Asymmetric optics at 4000 K suit recreational and area lighting. Surge is listed at 6/8 kV on ClearFlood gen2, lower than heavy-duty floods, and SmartBright G3 stops at 120 lm/W.

14. LEDVANCE: Best for North American contractors who want selectable wattage and beam on one fixture

Headquarters: Garching bei Muenchen, Germany · Founded: July 2016 · Type: general lighting manufacturer active in more than 140 countries

Official website: https://www.ledvance.com/

Main products: Floodlight Opti-Select, Security Floodlight, Floodlight Hazardous Location

Flood model and specs: US flood category includes selectable wattage, color temperature and beam-angle models; Opti-Select S470: 350/400/470 W, up to 68,150 lm, up to 145 lm/W, DLC Premium, 5-year warranty

Certifications / notable work: lists 50+ branches and business in more than 140 countries

LEDVANCE does business in more than 140 countries, and its US range spans security lighting through hazardous-location floods. Selectable models cut the stock count on small jobs. Its Opti-Select page lists building facades, loading docks and perimeter and security lighting among its uses. Opti-Select stops at 470 W and 68,150 lumens, far below the stadium floods here, and its cULus listing and US and Canada warranty terms leave jobs outside North America needing another line.

15. Schreder: Best for stadiums and large areas that need very high lumens and 20 kV surge options

Headquarters: Liege, Belgium · Founded: 1907 · Type: family-founded lighting manufacturer

Official website: https://www.schreder.com/

Main products: OMNIBLAST and OMNISTAR-MIDI LED floodlights

Flood model and specs: OMNIBLAST: 40,700-247,400 lm, 367-1,740 W, up to 172 lm/W, 10 or 20 kV surge; OMNISTAR-MIDI: 32,318 lm at 226 W

Certifications / notable work: OMNIBLAST UL certified option; OMNISTAR-MIDI Zone 2 and 21/22 versions

OMNIBLAST has one of the highest outputs here, and each module tilts up to 40 degrees, which lets a designer shape light across a pitch. Its DMX-RDM control suits event lighting, including light shows before, during and after matches. OMNIBLAST is built around remote gear, so the install must plan a separate gear box and cable run.

16. Lena Lighting: Best for European industrial sites that need C5 housings and IK10 impact resistance

Headquarters: Sroda Wielkopolska, Poland · Founded: 1989 · Type: manufacturer listed on the Warsaw Stock Exchange since 2005

Official website: https://lenalighting.com/

Main products: Factor LED, Factor LED XL and Quest LED Evo floodlights

Flood model and specs: Factor LED 14,600-150,800 lm, 10-120 degree beams, IP66, IK09; Quest LED Evo up to 200 lm/W, IP67, IK10, C5

Certifications / notable work: Quest LED Evo C5-rated die-cast housing; customers in as many as 70 countries

Lena rates Quest LED Evo for 50 °C, heavy dust and humidity, which suits hot, dusty yards, and its Factor LED one-module size calculates to 148.5 lm/W at 101 W. Beam choices down to 10 degrees help on tall masts. Factor LED stops at IK09 and uses CRI 70-80 optics, so a site that needs IK10 has to move to Quest LED Evo.

17. Thorn Lighting: Best for sports and high-column area lighting that must limit light spill

Headquarters: Spennymoor, County Durham, United Kingdom · Founded: 1928 · Type: lighting manufacturer within the Zumtobel Group

Official website: https://www.thornlighting.com/

Main products: Altis and Champion LED floodlights for sports and area lighting

Flood model and specs: Altis delivers up to 217,000 lm for sports and high column area lighting applications

Certifications / notable work: listed by SAPCA as an approved manufacturer to the sports and play industry, with a manufacturing site in the North East of England

Thorn calls Altis easy to install, lets each LED module tilt to reduce the number of floods, and headlines the fixture on controlled light pollution, the reason a council near homes might pick it over a brighter rival. Apart from standalone one-module versions, Altis Gen5 needs a separately supplied gearbox, and Thorn’s datasheet says the external control gear is supplied only by Thorn, so replacement gear is single-source.

China Factory-Direct LED Flood Light Exporters (Companies 18–20)

China LED flood exporters: OPPLE at 80 and 130 lm/W, AGC up to 180 lm/W on FL55, Hpwinner simulates each project first.

Those looking for an LED floodlight manufacturer in China should compare tiers first since the same factory may ship both a budget and a high-output line. The LED floodlight industry there offers a diverse product mix, so name the efficacy tier in your RFQ. These three brands in China publish flood figures or project data.

18. OPPLE Lighting: Best for trade buyers who want one maker covering budget and high-output floods

Headquarters: Shanghai, China · Founded: 1996 · Type: integrated lighting manufacturer covering R&D, production, distribution and after-sales

Official website: https://www.opple.com/

Main products: Performer HO, EQ and EcoMax LED floodlights

Flood model and specs: Performer HO up to 80,000 lm and 130 lm/W, 1-10V dimmable, IP66, IK08; EcoMax II up to 80 lm/W, IP65, IK08

Certifications / notable work: reports over 30,000 sales outlets in China

OPPLE offers both entry-level and higher-output flood families at 80 and 130 lm/W, so a distributor can cover two efficacy tiers from one maker. Performer HO adds 1-10V dimming for industrial yards. The EcoMax II line reaches about 80-83 lm/W, below the 118 lm/W federal line, so the tier must be named in the order.

19. AGC Lighting: Best for OEM and private-label export orders that need high lm/W

Headquarters: Shenzhen, China · Founded: 2014 · Type: designer and manufacturer of industrial, outdoor and hazardous-area lighting, with OEM and ODM service

Official website: https://www.agcled.com/

Main products: FL35, FL55 and FL87 LED flood lights, with explosion-proof floods for hazardous sites

Flood model and specs: FL35 up to 240,000 lm; FL55 50-300 W at up to 180 lm/W with PC lens; FL87-C5 400-600 W at 145-165 lm/W

Certifications / notable work: according to its website, ISO 9001, ISO 14001 and ISO 50001, with explosion-proof products certified to IECEx, ATEX and UL844; reports 120+ countries and 9 million+ fixtures

AGC runs a 37,350 sqm factory in Shenzhen and an overseas plant in Vietnam, which gives importers a route around single-country supply, and its FL35 is the highest catalog output among the Chinese makers here. The 180 lm/W FL55 figure applies to the PC lens; the glass version is listed at 160 lm/W. Its FL57 and FL84 pages list a 5-year warranty, half of Dialight’s 10, and explosion-proof floods sit on a separate AGC site, so a hazardous order is a separate inquiry.

20. Hpwinner: Best for municipal and airport projects simulated before quotation

Headquarters: Gongshu District, Hangzhou, Zhejiang, China · Founded: July 2011 · Type: LED outdoor lighting manufacturer with a staff of over 800

Official website: https://www.hpwinner.com/

Main products: LED high-mast floods, airport, harbor and stadium flood lights, and wall-mounted floods

Flood model and specs: lumens set by project simulation; the flood page gives about 130-170 lm/W as the average for LED floodlights

Certifications / notable work: reports 700+ patents and 400,000 square metres of building area

Hpwinner runs a simulation first and then picks the floodlight and lighting solutions, which suits an owner buying a whole airport apron or harbor rather than a single fixture. The range leads with street and roadway lighting, and the flood page says lumens are set by project simulation rather than a fixed table.

How to Choose an LED Flood Light Manufacturer

Eight checks for choosing an LED flood light manufacturer, from efficacy at your size to MOQ and route to buy.

Assess the job first and then assess each candidate against these eight checks. Certificates, first article inspection, and country of origin are part of this review of product quality, as a catalog claim stays a claim until you see the documents for your exact fixture.

  1. Efficacy at the size you order. The listed lumens divided by the listed watts give the efficacy of that configuration, which can be compared with 118 lm/W. Efficacy can be compared across different sizes of fixture under similar operating conditions and light quality specifications. A brighter flood at lower lm/W can still cost more to run, so judge brightness and energy efficiency together.
  2. Delivered light. Ask for an IES or LDT file and a layout showing target illumination at your mounting height, because lumen output alone says nothing about the work plane. Hpwinner starts from the site for this reason.
  3. Beam and mount. State the NEMA beam type or beam spread and slipfitter, trunnion, or knuckle mount. Lena’s Factor LED can provide beam angles from 10 to 120 degrees; a narrow beam angle concentrates the light on a distant aiming point and a layout confirms whether a wide beam angle is suitable for a perimeter walkway. Request color temperature and color rendering simultaneously.
  4. Ingress, impact and corrosion. Read IP for outdoor use and IK for fixtures in high-traffic areas within reach of equipment, and ask for a stated corrosion class for coastal sites. Quest LED Evo states C5 with IP67 and IK10, while an IP66 label by itself says nothing about salt.
  5. Surge. Compare the kV figure on the sheet. Signify ClearFlood gen2 lists 6/8 kV and Schreder OMNIBLAST lists 10 or 20 kV options, and ask each maker which protection mode and test condition its figure uses.
  6. Hazardous marking. Read the exact model marking; Division 2 doesn’t cover Division 1 and an IP rating isn’t an approval. Our guide to hazardous location lighting markings explains the systems and the certificate-to-site match check examines one quote. Our hazardous location lighting page suggests the inputs to send.
  7. Warranty and rebates. Compare warranty years, from 5 at RAB to 10 at Dialight, ask who handles customer support on a failed fixture, weigh cost-effectiveness over those years, and check whether your size appears on the DLC list before counting on a rebate.
  8. Order terms. Ask for MOQ, sample time, production time and route to buy, then put them in a project-ready RFQ builder so bids compare like for like. Published figures are scarce: LFADJ lists a 50-100 piece planning MOQ on explosion-proof flood project orders, and RAB sells only through distributors.

What’s changing in 2026: DLC efficacy thresholds

The DesignLights Consortium raised its bar: under SSL V6.0, minimum efficacy thresholds increased by approximately 14 percent across solid-state lighting categories. That shifts which floods qualify for utility rebates, so a new LED fixture listed under an older version may not carry the same incentive on your next project. DLC calls these updates the most significant revisions to its core policies in more than half a decade, and rebate programs across the lighting industry read from its lists. Ask the maker which DLC version the listing sits under before you build a payback on it.

FAQ About LED Flood Light Manufacturers

Q: Which is the best LED flood light manufacturer for industrial sites?

For hazardous plants, Dialight and Warom; for ports and high-mast yards, Phoenix Lighting; for corrosive European sites, Lena Lighting; for North American retrofits through a wholesaler, RAB Lighting. The right pick follows your marking, your mounting height and how you buy, since no single maker leads on all three.

Our explosion-proof LED flood light layout guide covers the next step after a classified area is identified.

Q: Who is the largest LED flood light manufacturer in the world?

No public ranking names the largest maker by floodlight units, so flood-specific market share is unknown. Across all lighting, Signify describes itself as the world’s leading lighting company and is listed on Euronext Amsterdam. Size also says little about fit, since a smaller maker can win a stadium or Division 1 job outright.

Q: Who makes LED flood lights in the USA?

Larson Electronics in Texas says the lights in its explosion-proof category are made in the USA, and Lithonia offers a Buy America(n) option. Musco in Oskaloosa, Phoenix Lighting in Milwaukee and RAB Lighting in Cranbury are also headquartered in the USA, though a US headquarters does not show where a given fixture is built.

Q: What is the difference between an LED flood light manufacturer and a supplier?

A manufacturer produces fixtures from its own designs or supplied designs, and custom engineering can adapt drivers and optics. A supplier may only resell, so ask who holds the test reports and warranty.

Q: How much does a commercial LED flood light cost from a manufacturer?

A wattage-selectable 200-300 W commercial area light for parking lots was on sale at about $220 online (regular $263.99), and an explosion-proof unit costs far more. Warehouse Lighting showed a 200/240/300 W selectable Quasar G4 at $219.99 in November 2026, while Larson Electronics listed its explosion-proof EPL-LED-100W-RT at $3,612.24 for 100 W. Factory quotes change with driver brand, efficacy tier, certification and order size, so ask each maker to quote the same wattage, lumens and warranty.

Project terms matter as much as price. LFADJ schedules explosion-proof production 25-35 days after deposit, with a 50-100 piece planning MOQ per model. See our page on explosion-proof lighting principles for what drives the certified-fixture premium.

Q: Is an IP66 LED flood light the same as an explosion-proof flood light?

No. IP66 protects against dust and water, but explosion protection requires a model-specific Class/Division or Zone marking for your location.

Choosing Among These LED Flood Light Suppliers

Choose an LED flood supplier after fixing mounting height, beam and hazardous classification; moving sites can use towers.

Different makers suit different jobs: hazardous-area and heavy-industry flood builders, North American commercial lines, European project floods and China factory-direct exporters. First determine the mounting height, desired illuminance, beam, site conditions, and any hazardous classification, and then choose the most appropriate supplier. For temporary sites that move every few weeks, mobile light towers can take the place of a fixed flood.

If your project involves a classified area, send your site requirements to LFADJ with your drawing, annual quantity, hazard group and required delivery date, and ask for a technical review and quotation.

About This Analysis

This list compares LED flood light makers using watts, lumens and markings read from their own pages in November 2026, with lm/W calculated where a maker lists only watts and lumens. LFADJ builds explosion-proof and mobile lighting and is listed first as the publisher. Figures were traced back to those makers’ pages by the Zhejiang Longfa Lighting editorial desk.

References & Sources

  1. Purchasing Energy-Efficient Exterior Lighting US Department of Energy, Federal Energy Management Program
  2. Reflecting on 2025, Building in 2026 DesignLights Consortium
LFADJ · COMPANY & TECHNICAL CONTEXT
Practical lighting guidance for real project conditions

LFADJ shares product context, application notes, and selection checks to help project teams compare industrial lighting options with the right site details in view.

What LFADJ covers

LFADJ focuses on industrial lighting and tailored lighting solutions for teams planning, specifying, or operating demanding work environments.

  • Product context: mobile lighting, light towers, explosion-proof lighting, emergency lighting, and related industrial lighting equipment.
  • Project context: application conditions, target illumination, runtime, site constraints, and product configuration questions.
  • Decision support: use the information here as a starting point, then confirm final specifications against the actual installation and local requirements.
Industrial lighting Application guidance Project enquiries
NEXT STEP
Have a site question?

Send the operating environment, lighting target, expected runtime, and any drawings or photos you have. The existing enquiry form is ready for a focused discussion.

Start an enquiry Or use the LFADJ contact page